Addressable Heat Detector
Tyco Minerva MX 830H addressable heat detector operating in fixed-temperature and rate-of-rise modes with approved sensitivities; suited to dusty environments where smoke detectors are unsuitable.
Smoke, Heat and Carbon Monoxide Multi-Sensor Detector
Tyco Minerva MX 830PC 3oTec multi-sensor detector monitoring smoke, heat and CO levels in concert for accurate fire detection.
Addressable Optical Smoke Detector
Tyco Generation 6 MX 835P addressable optical smoke detector using the Zettler digital protocol for robust communication to the control panel.
Triple Sensor Detector
Tyco Generation 6 MX 835PC 3oTec triple-sensor detector using the Zettler digital protocol; smoke, heat and CO sensing for fire detection.
Addressable Optical Smoke Detector
Tyco Minerva MX 850P addressable optical smoke detector with built-in line isolator, selectable sensitivities and modes, two-way infrared communication.
Addressable Heat Detector
Tyco Minerva MX 850H addressable heat detector operating in fixed-temperature and rate-of-rise modes with built-in line isolator; suited to dusty environments.
Smoke, Heat and Carbon Monoxide Multi-Sensor Detector
Tyco Minerva MX 3oTec multi-sensor detector (model 850PC) monitoring smoke, heat and CO levels in concert for accurate fire detection with false alarm rejection.
Marine Optical Smoke and Heat Multi-Sensor Detector
Tyco Minerva MX 851PH marine combined optical and heat multi-sensor detector for a wide range of fires; selectable approved modes and sensitivities.
Addressable Optical Smoke and Heat Multi-Sensor Detector with Built-in Line Isolator
Tyco Generation 6 MX 855PH addressable optical smoke and heat multi-sensor detector with built-in line isolator, using the Zettler digital protocol.
Addressable Optical Smoke Detector with Built-in Line Isolator
Tyco Generation 6 MX 855P addressable optical smoke detector with built-in line isolator, using the Zettler digital protocol.
Addressable Heat Detector with Built-in Line Isolator
Tyco Generation 6 MX 855H addressable heat detector with built-in line isolator, using the Zettler digital protocol.
Triple Sensor Detector with Built-in Line Isolator
Tyco Generation 6 MX 855PC 3oTec triple-sensor detector with built-in line isolator, using the Zettler digital protocol.
Conventional Rate-of-Rise Heat Detector 60C
Tyco Fireclass 701H conventional rate-of-rise heat detector for use with Fireclass conventional fire alarm panels; uses algorithms to determine fire conditions precisely.
Conventional Fixed Temperature Heat Detector 60C
Tyco Fireclass 702H conventional fixed-temperature heat detector (60C, EN) using algorithms to determine fire conditions for improved false alarm rejection.
Conventional Fixed Temperature Heat Detector 90C
Tyco Fireclass 703H conventional fixed-temperature heat detector (90C) for use with Fireclass conventional fire alarm panels.
Marine Conventional Optical Smoke Detector
Tyco 711P marine conventional optical smoke detector sensing optical scatter from smoke particles; microprocessor-based, for conventional 2-wire detection systems.
Conventional Optical Heat and Smoke Detector
Tyco 701PH conventional optical heat and smoke multi-sensor detector; senses optical scatter from smoke particles with rate-of-rise temperature compensation.
Conventional Rate-of-Rise and Fixed Temperature Heat Detector
Tyco 711H category A1R conventional heat detector using both rate-of-rise and fixed-temperature sensing (static response 54C to 65C), for conventional two-wire detection systems.
XP95 Marine Flame Detector (IR3)
Apollo XP95 marine flame detector (IR3), base mounted. Protects indoor areas including dirty or smoky conditions; three IR sensors respond to different IR wavelengths to discriminate flames from spurious radiation. Responds to stationary flames with no flicker.
Series 65 Heat Detector
Apollo Series 65 heat detector. Monitors temperature via a dual-thermistor network providing voltage output proportional to air temperature. Suitable for dirty or smoky environments; wide operating voltage; flashing LED and magnet-operated test switch option. 6 V.
Series 65 Optical Smoke Detector (Flashing LED)
Apollo Series 65 optical smoke detector with flashing LED. Uses light-sensing technology to detect smoke; indicator LED clear in quiescent state, red in alarm. Suited to slow-burning, smouldering fires.
Series 65 Optical Smoke Detector
Apollo Series 65 optical smoke detector. Uses light-sensing technology to detect smoke; indicator LED clear in quiescent state, red in alarm. Suited to slow-burning, smouldering fires.
XP95 Heat Detector (A2S)
Apollo XP95 heat detector (A2S). Single thermistor providing count output proportional to air temperature, alarm at 55 C. Operates from -20 C to +70 C; unaffected by wind and atmospheric pressure.
XP95 Optical Smoke Detector
Apollo XP95 optical smoke detector. Uses the light scatter principle to detect slow-burning and smouldering fires. Operates from -20 C to +60 C; insect-resistant screen.
XP95 I.S. Optical Smoke Detector
Apollo XP95 I.S. (intrinsically safe) optical smoke detector. Uses the light scatter principle to detect slow-burning and smouldering fires. Operates from -20 C to +60 C; insect-resistant screen.
Conventional Marine Manual Call Point
Apollo conventional marine manual call point. Manually initiates an alarm signal on the fire detection system. Weatherproof, EN 54-11 certified, plug-and-play terminal connections, continuity link for wiring test. Operating temperature 10-55 C, 93% RH max.
Conventional Marine Manual Call Point (Outdoor)
Apollo conventional marine manual call point for outdoor use. Manually initiates an alarm signal. Weatherproof, EN 54-11 certified, plug-and-play terminal connections. Operating temperature -25 to 70 C.
Addressable Wall Sounder
Tyco P85SR addressable wall sounder, part of the P80S range of compact addressable wall sounders; IP-rated version for outdoor or harsh environments, low current and high output.
Alarm Bell with Base
Tyco fire alarm bell with mounting base.
Loop Powered Sounder Module
Tyco LPS800 loop-powered sounder module switching up to 75 mA at 24 V DC to activate external notification devices, with normal/short/open circuit monitoring and short-circuit protection.
Discovery Marine Heat Detector [SIL2]
Apollo Discovery marine heat detector [SIL2]. Low airflow resistance case with single thermistor sensing air temperature. Operates from -40 C to +70 C, five operating modes. 28 V.
Discovery Marine Optical Smoke Detector [SIL2]
Apollo Discovery marine optical smoke detector [SIL2]. High-specification light scatter device that detects fire while managing false alarms. Operates from -40 C to +70 C, five operating modes.
Discovery Marine Multi-Sensor Detector (Optical/Heat) [SIL2]
Apollo Discovery marine multi-sensor detector [SIL2] combining optical smoke and thermistor temperature sensors for improved false-alarm management. Operates from -40 C to +70 C, five operating modes, drift compensation.
Discovery Marine Manual Call Point (Outdoor, Isolating)
Apollo Discovery marine manual call point, outdoor isolating. Manually initiates an alarm signal. EN 54-11 and EN 54-17 certified, resettable element, 170 degree viewable LED, XP95 and Discovery compatible. Protocol voltage 5-9 V.
Safety-Related Controller
The HIMA 6080165 is a safety-related automation/controller module. 24 VDC input/output, 8 input and 8 output channels, Modbus RTU communication, operating -20 to 60 C.
Logic Manager Module
Honeywell IPC 620 Logic Manager Module (LMM) for the TDC 3000 DCS, acting as UCN interface and control processor executing ladder logic and collecting I/O subsystem data.
Logic Manager Module
Honeywell 621-0071 logic manager module providing a scalable platform for control and monitoring functions. 24 VDC, 300 mA, 7.2 W; modular design for expansion.
Sounder Beacon with Blue Lens
Tyco Flashni XE audible and visual sounder/beacon with blue lens; xenon beacon with independent flash control for staged alerts, single installation point.
Hydrogen Sulphide (H2S) Gas Detection Tube (1-200 ppm)
Draeger short-term detector tube for hydrogen sulphide, measuring range 1 to 200 ppm. Used for concentration peaks, inhalation-area exposure, leak detection and air analysis in confined spaces.
Nitrogen Dioxide Gas Detection Tube 2/c (2-100 ppm)
Draeger short-term detector tube for nitrogen dioxide (2/c), default measuring ranges 5 to 100 ppm and 2 to 50 ppm, measurement time approx. 1 to 2 min.
Acetaldehyde 100/a Gas Detection Tube
Draeger short-term gas detection tube for acetaldehyde, type 100/a. Measuring range 100-1,000 ppm, measurement time 5 min. Glass vial with chemical reagent read by colour-change length using the Draeger Accuro bellows pump.
Hydrogen Sulphide (H2S) Gas Detection Tube (0.5-15 ppm)
Draeger short-term detector tube for hydrogen sulphide, measuring range 0.5 to 15 ppm. Used for concentration peaks, exposure measurement, leak detection and air analysis in confined spaces.
Benzene Gas Detection Tube 5/b (5-50 ppm)
Draeger short-term detector tube for benzene, measuring range 5 to 50 ppm, 20 pump strokes, measurement time approx. 8 min, standard deviation +/- 10 to 15%, color change white to brown-green.
Oxygen Gas Detection Tube 5%/b (5-23 vol%)
Draeger short-term detector tube for oxygen (5%/B), default measuring range 5 to 23 vol.%, measurement time approx. 1 min.
Nitric Acid Gas Detection Tube 1/a (1-50 ppm)
Draeger short-term detector tube for nitric acid (1/a), default measuring ranges 5 to 50 ppm and 1 to 15 ppm, measurement time approx. 2 to 4 min.
Phosphoric Acid Esters 0.05/a Gas Detection Tube
Draeger short-term gas detection tube for phosphoric acid esters/ethers, type 0.05/a (dual use). Glass vial with chemical reagent; a calibrated air sample is drawn through with the Draeger Accuro bellows pump and the colour-change length indicates concentration.
Petroleum Hydrocarbons 100/a Gas Detection Tube
Draeger gas detection tube for petroleum hydrocarbons, type 100/a. Standard measuring range 100-2,500 ppm (n-octane), 2 strokes, ~30 s measurement, color change white to green, 0-40 C.
Carbon Monoxide Gas Detection Tube 2/a (2-300 ppm)
Draeger short-term detector tube for carbon monoxide (2/a), measuring range 2 to 300 ppm. Used for concentration peaks, exposure measurement, leak detection and air analysis in confined spaces.