CATALOGUE / ALL REFERENCES

Parts catalogue

Browse by category, product type and truck or manufacturer brand. No public pricing; each reference routes to wholesale enquiry.

986 references
516.830.053
Heat DetectorTyco

Addressable Heat Detector

Tyco Minerva MX 830H addressable heat detector operating in fixed-temperature and rate-of-rise modes with approved sensitivities; suited to dusty environments where smoke detectors are unsuitable.

516.830.054
Multi-Sensor DetectorTyco

Smoke, Heat and Carbon Monoxide Multi-Sensor Detector

Tyco Minerva MX 830PC 3oTec multi-sensor detector monitoring smoke, heat and CO levels in concert for accurate fire detection.

516.835.052
Smoke DetectorTyco

Addressable Optical Smoke Detector

Tyco Generation 6 MX 835P addressable optical smoke detector using the Zettler digital protocol for robust communication to the control panel.

516.835.054
Multi-Sensor DetectorTyco

Triple Sensor Detector

Tyco Generation 6 MX 835PC 3oTec triple-sensor detector using the Zettler digital protocol; smoke, heat and CO sensing for fire detection.

516.850.052
Smoke DetectorTyco

Addressable Optical Smoke Detector

Tyco Minerva MX 850P addressable optical smoke detector with built-in line isolator, selectable sensitivities and modes, two-way infrared communication.

516.850.053
Heat DetectorTyco

Addressable Heat Detector

Tyco Minerva MX 850H addressable heat detector operating in fixed-temperature and rate-of-rise modes with built-in line isolator; suited to dusty environments.

516.850.054
Multi-Sensor DetectorTyco

Smoke, Heat and Carbon Monoxide Multi-Sensor Detector

Tyco Minerva MX 3oTec multi-sensor detector (model 850PC) monitoring smoke, heat and CO levels in concert for accurate fire detection with false alarm rejection.

516.850.055
Multi-Sensor DetectorTyco

Marine Optical Smoke and Heat Multi-Sensor Detector

Tyco Minerva MX 851PH marine combined optical and heat multi-sensor detector for a wide range of fires; selectable approved modes and sensitivities.

516.855.051
Multi-Sensor DetectorTyco

Addressable Optical Smoke and Heat Multi-Sensor Detector with Built-in Line Isolator

Tyco Generation 6 MX 855PH addressable optical smoke and heat multi-sensor detector with built-in line isolator, using the Zettler digital protocol.

516.855.052
Smoke DetectorTyco

Addressable Optical Smoke Detector with Built-in Line Isolator

Tyco Generation 6 MX 855P addressable optical smoke detector with built-in line isolator, using the Zettler digital protocol.

516.855.053
Heat DetectorTyco

Addressable Heat Detector with Built-in Line Isolator

Tyco Generation 6 MX 855H addressable heat detector with built-in line isolator, using the Zettler digital protocol.

516.855.054
Multi-Sensor DetectorTyco

Triple Sensor Detector with Built-in Line Isolator

Tyco Generation 6 MX 855PC 3oTec triple-sensor detector with built-in line isolator, using the Zettler digital protocol.

516.900.003
Heat DetectorTyco

Conventional Rate-of-Rise Heat Detector 60C

Tyco Fireclass 701H conventional rate-of-rise heat detector for use with Fireclass conventional fire alarm panels; uses algorithms to determine fire conditions precisely.

516.900.004
Heat DetectorTyco

Conventional Fixed Temperature Heat Detector 60C

Tyco Fireclass 702H conventional fixed-temperature heat detector (60C, EN) using algorithms to determine fire conditions for improved false alarm rejection.

516.900.005
Heat DetectorTyco

Conventional Fixed Temperature Heat Detector 90C

Tyco Fireclass 703H conventional fixed-temperature heat detector (90C) for use with Fireclass conventional fire alarm panels.

516.900.101
Smoke DetectorTyco

Marine Conventional Optical Smoke Detector

Tyco 711P marine conventional optical smoke detector sensing optical scatter from smoke particles; microprocessor-based, for conventional 2-wire detection systems.

516.900.102
Multi-Sensor DetectorTyco

Conventional Optical Heat and Smoke Detector

Tyco 701PH conventional optical heat and smoke multi-sensor detector; senses optical scatter from smoke particles with rate-of-rise temperature compensation.

516.900.103
Heat DetectorTyco

Conventional Rate-of-Rise and Fixed Temperature Heat Detector

Tyco 711H category A1R conventional heat detector using both rate-of-rise and fixed-temperature sensing (static response 54C to 65C), for conventional two-wire detection systems.

55000-029MAR
Flame DetectorApollo

XP95 Marine Flame Detector (IR3)

Apollo XP95 marine flame detector (IR3), base mounted. Protects indoor areas including dirty or smoky conditions; three IR sensors respond to different IR wavelengths to discriminate flames from spurious radiation. Responds to stationary flames with no flicker.

55000-132APO
Heat DetectorApollo

Series 65 Heat Detector

Apollo Series 65 heat detector. Monitors temperature via a dual-thermistor network providing voltage output proportional to air temperature. Suitable for dirty or smoky environments; wide operating voltage; flashing LED and magnet-operated test switch option. 6 V.

55000-316APO
Smoke DetectorApollo

Series 65 Optical Smoke Detector (Flashing LED)

Apollo Series 65 optical smoke detector with flashing LED. Uses light-sensing technology to detect smoke; indicator LED clear in quiescent state, red in alarm. Suited to slow-burning, smouldering fires.

55000-317APO
Smoke DetectorApollo

Series 65 Optical Smoke Detector

Apollo Series 65 optical smoke detector. Uses light-sensing technology to detect smoke; indicator LED clear in quiescent state, red in alarm. Suited to slow-burning, smouldering fires.

55000-420APO
Heat DetectorApollo

XP95 Heat Detector (A2S)

Apollo XP95 heat detector (A2S). Single thermistor providing count output proportional to air temperature, alarm at 55 C. Operates from -20 C to +70 C; unaffected by wind and atmospheric pressure.

55000-620APO
Smoke DetectorApollo

XP95 Optical Smoke Detector

Apollo XP95 optical smoke detector. Uses the light scatter principle to detect slow-burning and smouldering fires. Operates from -20 C to +60 C; insect-resistant screen.

55000-640APO
Smoke DetectorApollo

XP95 I.S. Optical Smoke Detector

Apollo XP95 I.S. (intrinsically safe) optical smoke detector. Uses the light scatter principle to detect slow-burning and smouldering fires. Operates from -20 C to +60 C; insect-resistant screen.

55100-021MAR
Call PointApollo

Conventional Marine Manual Call Point

Apollo conventional marine manual call point. Manually initiates an alarm signal on the fire detection system. Weatherproof, EN 54-11 certified, plug-and-play terminal connections, continuity link for wiring test. Operating temperature 10-55 C, 93% RH max.

55100-022MAR
Call PointApollo

Conventional Marine Manual Call Point (Outdoor)

Apollo conventional marine manual call point for outdoor use. Manually initiates an alarm signal. Weatherproof, EN 54-11 certified, plug-and-play terminal connections. Operating temperature -25 to 70 C.

576.080.005
Sounder BeaconTyco

Addressable Wall Sounder

Tyco P85SR addressable wall sounder, part of the P80S range of compact addressable wall sounders; IP-rated version for outdoor or harsh environments, low current and high output.

576.501.022.T
Sounder BeaconTyco

Alarm Bell with Base

Tyco fire alarm bell with mounting base.

577.800.011
Sounder BeaconTyco

Loop Powered Sounder Module

Tyco LPS800 loop-powered sounder module switching up to 75 mA at 24 V DC to activate external notification devices, with normal/short/open circuit monitoring and short-circuit protection.

58000-400MAR
Heat DetectorApollo

Discovery Marine Heat Detector [SIL2]

Apollo Discovery marine heat detector [SIL2]. Low airflow resistance case with single thermistor sensing air temperature. Operates from -40 C to +70 C, five operating modes. 28 V.

58000-600MAR
Smoke DetectorApollo

Discovery Marine Optical Smoke Detector [SIL2]

Apollo Discovery marine optical smoke detector [SIL2]. High-specification light scatter device that detects fire while managing false alarms. Operates from -40 C to +70 C, five operating modes.

58000-700MAR
Multi-Sensor DetectorApollo

Discovery Marine Multi-Sensor Detector (Optical/Heat) [SIL2]

Apollo Discovery marine multi-sensor detector [SIL2] combining optical smoke and thermistor temperature sensors for improved false-alarm management. Operates from -40 C to +70 C, five operating modes, drift compensation.

58200-976MAR
Call PointApollo

Discovery Marine Manual Call Point (Outdoor, Isolating)

Apollo Discovery marine manual call point, outdoor isolating. Manually initiates an alarm signal. EN 54-11 and EN 54-17 certified, resettable element, 170 degree viewable LED, XP95 and Discovery compatible. Protocol voltage 5-9 V.

6080165
Safety ControllerHIMA

Safety-Related Controller

The HIMA 6080165 is a safety-related automation/controller module. 24 VDC input/output, 8 input and 8 output channels, Modbus RTU communication, operating -20 to 60 C.

620-0071
Safety ControllerHoneywell

Logic Manager Module

Honeywell IPC 620 Logic Manager Module (LMM) for the TDC 3000 DCS, acting as UCN interface and control processor executing ladder logic and collecting I/O subsystem data.

621-0071
Safety ControllerHoneywell

Logic Manager Module

Honeywell 621-0071 logic manager module providing a scalable platform for control and monitoring functions. 24 VDC, 300 mA, 7.2 W; modular design for expansion.

640015FULL-0046X
Sounder BeaconTyco

Sounder Beacon with Blue Lens

Tyco Flashni XE audible and visual sounder/beacon with blue lens; xenon beacon with independent flash control for staged alerts, single installation point.

6719001
Gas Detection TubeDraeger

Hydrogen Sulphide (H2S) Gas Detection Tube (1-200 ppm)

Draeger short-term detector tube for hydrogen sulphide, measuring range 1 to 200 ppm. Used for concentration peaks, inhalation-area exposure, leak detection and air analysis in confined spaces.

6719101
Gas Detection TubeDraeger

Nitrogen Dioxide Gas Detection Tube 2/c (2-100 ppm)

Draeger short-term detector tube for nitrogen dioxide (2/c), default measuring ranges 5 to 100 ppm and 2 to 50 ppm, measurement time approx. 1 to 2 min.

6726665
Gas Detection TubeDraeger

Acetaldehyde 100/a Gas Detection Tube

Draeger short-term gas detection tube for acetaldehyde, type 100/a. Measuring range 100-1,000 ppm, measurement time 5 min. Glass vial with chemical reagent read by colour-change length using the Draeger Accuro bellows pump.

6728041
Gas Detection TubeDraeger

Hydrogen Sulphide (H2S) Gas Detection Tube (0.5-15 ppm)

Draeger short-term detector tube for hydrogen sulphide, measuring range 0.5 to 15 ppm. Used for concentration peaks, exposure measurement, leak detection and air analysis in confined spaces.

6728071
Gas Detection TubeDraeger

Benzene Gas Detection Tube 5/b (5-50 ppm)

Draeger short-term detector tube for benzene, measuring range 5 to 50 ppm, 20 pump strokes, measurement time approx. 8 min, standard deviation +/- 10 to 15%, color change white to brown-green.

6728081
Gas Detection TubeDraeger

Oxygen Gas Detection Tube 5%/b (5-23 vol%)

Draeger short-term detector tube for oxygen (5%/B), default measuring range 5 to 23 vol.%, measurement time approx. 1 min.

6728311
Gas Detection TubeDraeger

Nitric Acid Gas Detection Tube 1/a (1-50 ppm)

Draeger short-term detector tube for nitric acid (1/a), default measuring ranges 5 to 50 ppm and 1 to 15 ppm, measurement time approx. 2 to 4 min.

6728461
Gas Detection TubeDraeger

Phosphoric Acid Esters 0.05/a Gas Detection Tube

Draeger short-term gas detection tube for phosphoric acid esters/ethers, type 0.05/a (dual use). Glass vial with chemical reagent; a calibrated air sample is drawn through with the Draeger Accuro bellows pump and the colour-change length indicates concentration.

6730201
Gas Detection TubeDraeger

Petroleum Hydrocarbons 100/a Gas Detection Tube

Draeger gas detection tube for petroleum hydrocarbons, type 100/a. Standard measuring range 100-2,500 ppm (n-octane), 2 strokes, ~30 s measurement, color change white to green, 0-40 C.

6733051
Gas Detection TubeDraeger

Carbon Monoxide Gas Detection Tube 2/a (2-300 ppm)

Draeger short-term detector tube for carbon monoxide (2/a), measuring range 2 to 300 ppm. Used for concentration peaks, exposure measurement, leak detection and air analysis in confined spaces.